Fire curtains МВА from EI15 to EI180
The price of flame-retardant and smoke-proof barriers
The cost per square meter of the canvas can be viewed on the page of the products you need, but you need to take into account that the calculation was made without the cost of the drive (motor) and the protective box. Discounts are provided for large volumes. The price is calculated according to the program and varies depending on the size of the opening, the need for painting, the presence of irrigation at the facility and a backup power supply system.Fire-resistant curtains - screens according to GOST
Our products undergo mandatory certification and are tested according to GOST. Certificates and licenses can be viewed on the product page or the page with all certificates. Since 2020, we have been receiving certificates under the new regulation of the ТР ЕАЭС 043/2017.What are fire curtains?
Modern fire safety rules provide protection of production facilities, parking lots, warehouses, residential and office complexes, administrative buildings from fire and smoke with the help of a number of complex automatic systems integrated into a common fire protection system. Along with ventilation and smoke extraction, fire alarm, sensors and water irrigation, automatic fire curtains, barriers, curtains are important.
Where are fire curtains installed?
The MBA manufacturing company designs, manufactures and installs fireproof curtains for various horizontal and vertical openings of all sizes and purposes. According to the project of the building, depending on the purpose, size and design, fire curtains can be ordered for the following openings:
- elevator shafts;
- window openings;
- door and gate openings, including passageways and vestibule-locks indoors;
- entrance openings for transport and loading equipment;
- escalator spaces and atriums.
What are flame-retardant curtains for?
Anti-fire curtains act as fire-retardant barriers and prevent the spread of fire and gorenje products in the room. To limit the spread of smoke, smoke-proof curtains and membranes can be used, which I install permanently under the ceiling or which descend automatically to the level of the smoke layer. A fire barrier (curtain, membrane, curtain, curtain) can be single-layer and multi-layer. A single-layer curtain is installed in rooms where there is an irrigation system and increased fire resistance is achieved due to the joint work of the canvas and water irrigation. Multi-layer anti-fire curtain can be installed in rooms where there is no irrigation system. Fire resistance is achieved due to the multilayer construction of the web with a layer of carbon filler.
Requirements for the quality of fire curtains and fabric
In order for the fire curtains installed at your facility to be accepted by the fire inspection and they have served for a long time without breakdowns and problems, the curtains must fit a number of conditions:
the canvas should be strong and flexible;
non-toxic and non-flammable materials must be used;
chemically resistant properties;
for certain types and sizes of curtains, there should be reinforcement of the canvas with steel threads;
the metal of the structure must withstand high temperatures and not allow large deformations;
have a control unit for integration into the fire alarm and protection system;
according to Federal Law No. 123, it should be lowered automatically even when the electricity in the building is turned off.
What are the fire-retaining curtains of MBA (FireTechnics) made of
In order for fire curtains to function properly, when lowered, they divide the room into compartments to simplify the evacuation of people and contain the fire, they must consist of the following structural elements:
- fabric made of non-combustible certified fabric;
- a high-temperature swelling carbon layer for multilayer curtains, which provides additional fire protection;
- the presence of water irrigation when using a single-layer canvas and the need to raise the fire resistance to EI 120 or EI 180;
- electric drive for lowering and lifting the canvas; the drive control unit with emergency control buttons, which allows you to automatically close the barriers when a fire signal is received;
- metal protective box and guides;
- a cutting-off tire that helps to stretch the canvas when lowering and lifting. In the open state of the curtain, the tire is hidden in the recess of the box.
Advantages of FireShield and Stöbich Fire Pro fire curtains
- simplicity, reliability and quality of parts at a high level;
integration with any fire safety systems of domestic and foreign production;
complete set of barriers with high-quality European electric motors;
the minimum space occupied by the finished barrier under the ceiling and around the perimeter;
availability of state EAC certificates.х, FireTechnics, FireShield.
In our catalog of fire barriers, fire curtains and membranes are presented, allowing you to fully provide fire and smoke protection of a room for any purpose.
- multilayer automatic curtains without irrigation with fire resistance EI 60, 90, 120. They are perfect for rooms where water irrigation is not provided, it is required not to spoil the design and comply with fire safety rules;
- single-layer curtains with water irrigation and fire resistance EI 60, 120,180. Most often installed in hangars, underground parking lots and factories with splinker or drencher irrigation;
smoke barriers and membranes installed permanently or lowered automatically with integrity up to 120 minutes - E 120, which serve to divert gorenje products to smoke removal systems;
horizontal fire-retardant fire-shield curtains without irrigation EI 60, 120, preventing the spread of gorenje between floors and other horizontal openings; - automatic fire-fighting window curtains that prevent the transfer of fire between nearby buildings;
fire curtains of complex shape of the "accordion" type, which do not require intermediate guides and are installed in atriums and escalators;
barriers for conveyor openings of various types. -
HOW TO INSTALL CURTAIN-TYPE FIRE BARRIERS?
The price of turnkey fire curtains includes delivery and installation on site. Our craftsmen produce high-quality installation of non-flammable curtains throughout Russia and former CIS countries. In addition to manufacturing, we also carry out repairs and maintenance of fire-resistant barriers of various designs. There is a license of the Ministry of Emergency Situations and we are members of the SRO. "Installation supervision" and training of installers of our dealers is possible. Before installation, it is necessary to measure the opening, fill in the measuring sheet and prepare the opening, which includes the following:
- a metal frame is prepared if the opening has large irregularities or insufficient strength of the base, for example, the base is made of sandwich panels or foam blocks;
- free the lintel and side space from communications and structures interfering with installation;
supply electricity according to the power of the installed drive; - remove the "dry contact" for fire alarm control;
- agree on the conditions of unloading and the availability of lifting equipment.
Depending on the type of opening and other factors, installation is possible in several variants:
- Installation in the opening.
- The box is installed on the upper end of the opening and slightly narrows it.
- Installation on the opening.
- The box is installed on the wall above the opening without reducing the clearance.
- Suspended mounting on stilettos.
- Installation to ceiling beams.
- A complex shape of the curtain of the "accordion" type is possible.
Contact us! Our specialists will conduct a competent consultation and help determine the type of necessary curtains and installation.