Gates and curtains for parking lots and garages
Show more
Completed work on the installation of fire curtains, gates and industrial roller gates for underground parking lots and garages.
Such a number of flammable technical means and liquids under a residential building threatens a large fire with the slightest ignition. Cars are standing nearby, the fire will easily spread to neighboring rows and can threaten the entire building.
Fire protection in underground parking lots in new buildings is designed taking into account all mandatory requirements of laws and technical regulations. Exhaust ventilation, gas pollution sensors, water irrigation, alarm systems and fire barriers are installed. The management of all fire protection elements is reduced to a separate room, where the operator, using visual control and video surveillance, can control the entire system from the fire protection console.
Fire barriers (gates, curtains, screens) play an important role in protecting the entire building. In case of fire, the curtain gates block the spread of fire throughout the parking space, separate spaces of the underground parking and storage boxes. Having localized the fire in a confined space, it is easier to extinguish it with the help of built-in water irrigation or by the fire service.
To divide the space into fire-fighting compartments, passageways between boxes and parking sectors, vestibule-locks are used. To prevent a fire from spreading to the entire building, fire-resistant gates or curtains are installed at the entrance to the parking lot. Many mistakenly assume that fire gates can also perform the function of ordinary gates, open and close several hundred times a day. That's not so. It is necessary to duplicate fire gates and curtains with ordinary or high-speed gates. Our products were installed in pairs with both sectional and high-speed PVC gates. An ordinary gate of any design is placed on the outside, which can work quickly and withstand a large number of openings, and a fire barrier is mounted on the inside of the opening, which closes only in case of fire.
Our installers have experience in installing both fire-resistant curtains and fire-fighting gates in underground parking lots of different levels. Gates are most often mounted with the following design:
Standard parking gates are quite difficult to find, since the dimensions of the opening for the passage of cars are quite large and depend on the project. Even if standard dimensions are laid down according to the drawings of the building, then most often there are deviations in the dimensions of the opening and there will be problems with installation. Most companies produce fire-resistant barriers directly under a ready-made opening, taking into account its specifics, laid communications and the availability of free space on the side and top. Often the installation of products is impossible without preliminary preparation of the installation site.
The standard color of the guides and the box is galvanized, but for expensive LCDs, the overall finish and design are taken into account, which also applies to parking. To do this, the elements of the fire structure are painted to a certain color.
Astis residential complex on Vorobyovy Gory, whose underground garage walls are decorated with marble.
If necessary, it is possible to make elements from stainless steel.
Taking into account all these features, the price is also formed. The dimensions, the type of construction, the need for painting, installation features, the presence of irrigation and the power supply system are taken into account.
Why and how do fire barriers work in large modern parking lots
Modern underground parking in residential complexes are built taking into account the number of apartments in the house and should cover all the needs of residents for parking personal cars. Often, in addition to parking spaces in the underground space, there are also storerooms for storing tires, bicycles and other equipment. If the house is multi-storey and multi-apartment, then the area of underground parking can reach the size of several football fields with the ability to accommodate hundreds of cars.Such a number of flammable technical means and liquids under a residential building threatens a large fire with the slightest ignition. Cars are standing nearby, the fire will easily spread to neighboring rows and can threaten the entire building.
Fire protection in underground parking lots in new buildings is designed taking into account all mandatory requirements of laws and technical regulations. Exhaust ventilation, gas pollution sensors, water irrigation, alarm systems and fire barriers are installed. The management of all fire protection elements is reduced to a separate room, where the operator, using visual control and video surveillance, can control the entire system from the fire protection console.
Fire barriers (gates, curtains, screens) play an important role in protecting the entire building. In case of fire, the curtain gates block the spread of fire throughout the parking space, separate spaces of the underground parking and storage boxes. Having localized the fire in a confined space, it is easier to extinguish it with the help of built-in water irrigation or by the fire service.
Where fire-fighting and industrial gates are installed in residential complex parking lots and business centers
To divide the space into fire-fighting compartments, passageways between boxes and parking sectors, vestibule-locks are used. To prevent a fire from spreading to the entire building, fire-resistant gates or curtains are installed at the entrance to the parking lot. Many mistakenly assume that fire gates can also perform the function of ordinary gates, open and close several hundred times a day. That's not so. It is necessary to duplicate fire gates and curtains with ordinary or high-speed gates. Our products were installed in pairs with both sectional and high-speed PVC gates. An ordinary gate of any design is placed on the outside, which can work quickly and withstand a large number of openings, and a fire barrier is mounted on the inside of the opening, which closes only in case of fire.
Fire-resistant gates or curtains are installed in underground garages and parking lots
Our installers have experience in installing both fire-resistant curtains and fire-fighting gates in underground parking lots of different levels. Gates are most often mounted with the following design:
- sliding, with a limited lintel;
- rolled, with limited side spaces;
- sectional, with a limited height of the lintel and no free space on the side of the opening.
Integration of fire curtains and gates with the building's fire alarm system
Сейчас на рынке предлагают системы и пульты пожарной охраны разных типов и от разных производителей, зарубежных, отечественных. Не всё оборудование совместимо и не все функции поддерживают. Противопожарные преграды от производственной компании МВА легко интегрируются с любыми пультами и системами пожарной охраны. Для управления приводом ворот или штор на закрытие-открытие достаточно подвести «сухой контакт». При разрыве сухого контакта преграда закрывается, и не открывается до восстановления управляющего контакта. Управление может происходить как от пожарного пульта, так и по кнопке на блоке управления. Управление по кнопке используется для обслуживания и проверки работоспособности системы.Price and dimensions of gates and fire-resistant curtains for parking lots and underground garages
Standard parking gates are quite difficult to find, since the dimensions of the opening for the passage of cars are quite large and depend on the project. Even if standard dimensions are laid down according to the drawings of the building, then most often there are deviations in the dimensions of the opening and there will be problems with installation. Most companies produce fire-resistant barriers directly under a ready-made opening, taking into account its specifics, laid communications and the availability of free space on the side and top. Often the installation of products is impossible without preliminary preparation of the installation site.
The standard color of the guides and the box is galvanized, but for expensive LCDs, the overall finish and design are taken into account, which also applies to parking. To do this, the elements of the fire structure are painted to a certain color.
Astis residential complex on Vorobyovy Gory, whose underground garage walls are decorated with marble.
If necessary, it is possible to make elements from stainless steel.
Taking into account all these features, the price is also formed. The dimensions, the type of construction, the need for painting, installation features, the presence of irrigation and the power supply system are taken into account.